<article-title>ASSESSING THE BEHAVIOR OF COLUMN-SPLICE<br/>
CONNECTIONS BETWEEN CFSTS IN AXIAL<br/>
TENSION</article-title>
</title-group>

<author>AVIK SAHA<sup>1</sup>, SWAPAN SAHA<sup>2</sup>, BRIAN UY<sup>3</sup>, and DONGXU LI<sup>4</sup></author>

<aff><sup>1</sup>University of New South Wales, Five Dock, Australia<br/>
<sup>2</sup>School of Computing, Engineering and Mathematics, Western Sydney University,<br/>
Penrith, Australia<br/>
<sup>3</sup>School of Civil Engineering, University of Sydney, Camperdown, Australia<br/>
<sup>4</sup>School of Civil Engineering, University of New South Wales, Kensington, Australia</aff>


</article-meta></front>
<body>
<abstract>
<title>ABSTRACT</title>
<p>Increasing the sustainability of construction materials is a key goal in the construction
industry. As the demand for high-rise residential structures grows, new more efficient
methods of achieving sustainability are required. Rendering larger structures
demountable to enable the re-use of steel structural members is one solution. The aim
of this study was to investigate and assess the behavior of blind bolted column-column
connections between concrete filled steel tubes in axial tension. The investigation
aimed to address the need for accurate design guidelines for tensile members in the
composite design standards such as Eurocode 4 and encourage the use of column-
column connections in large-scale demountable structures. A numerical investigation
of the blind bolted column-column connection has been performed using ABAQUS.
The model consisted of two concrete filled square hollow steel sections connected
using sleeve plates welded to the top tube only, as well as 16 M20 Lindapter Hollo-
bolts connecting the tubes. The numerical investigation revealed that the sections
tested conformed with AS1170.1 regarding columns in tension. Results of the
numerical investigation have been compared against experimental results for a
continuous CFST and it was found that the connections performed better in tension.
The parametric analysis revealed no dependence of the shape of force-displacement
relationships on diameter to thickness ratio, concrete compressive strength or yield
stress.</p>
<p><italic>Keywords: </italic>CFST, Colum-column connection, Finite element, ABAQUS, Parametric
study.</p>